Grace fireproof thickness chart

WebWhere T = Thickness of coating in inches, W = Weight of steel column in pounds per linear foot, and D = Heated perimeter of steel column section in inches. The following table lists the thicknesses in metric units. Steel Size M/D 1 Hr Min Thickness, mm. 1-1/2 Hr Min Thickness, mm. 2 Hr Min Thickness, mm. 3 Hr Min Thickness, mm. W6x12 25.9 2.35 ... http://avi-sa.com/datasheets/Product%20Datasheet_Monokote%20Z-106.pdf

CAFCO 300 Series & CAFCO 400 Series UL Designs - Isolatek International

http://www.archcoatings.com/product-pdfs/Grace%20products/Z106.pdf Webmethod 102-120 pcf unit weight, 3000 psi compressive strength, vibrated, 4 to 7 percent air. Min thickness as measured to crests of steel floor and form units, 2-1/2 in. 3. Welded … phone shop arnold https://mariamacedonagel.com

MONOKOTE Z-106/G Gypsum based, medium density, …

WebSOUTHWEST TYPE 5GP A 15 lb./ft³ (240 kg/m³) SFRM intended for the fire protection of interior structural columns, beams, joists, decks, walls, roofs, girders, floors and pre-cast concrete units. It is tested and certified for fire resistance ratings up to 4 hours. Southwest Type 5GP is a trademark of the Southwest Fireproofing Products Company. Webt = the wall thickness of the tube (in.) The thickness of Spray-Applied Fire Resistive Materials for ratings of 3/4, 1, 1-1/2, 2, 3 and 4 h of a steel pipe or tube can be determined by the equation: h = R - 0.20 4.43 (A/P) Where: R = the hourly rating (hrs). h = the thickness of Spray-Applied Fire Resistive Materials, minimum 1/4 in., maximum 3 ... WebFIREPROOFING Product selection guide Grace Fireproofing Products For over 50 years, Grace Construction Products has developed a series of Monokote® technologies to … how do you spell amethyst correctly

Standards in Fireproofing - AWCI

Category:CEMENTITIOUS FIREPROOFING 07812 - Rite-Way Thermal

Tags:Grace fireproof thickness chart

Grace fireproof thickness chart

UL Designs & Thickness — Roof Assemblies Resource GCP …

WebDec 10, 2024 · Measurements Key to Quality Assurance. The effectiveness of an intumescent fire resistive coating depends on the coating thickness and its ability to retain the ash layer. Coating thickness typically ranges … http://www.fireproofing.pl/sites/default/files/zalaczniki/Monokote_MK-6_HY%20karta%20techniczna%20eng.pdf

Grace fireproof thickness chart

Did you know?

WebIt is in the fireproofing contrac- Thickness Test: This test is performed by using a thickness gauge, as it appears in the drawing. This gauge is approved by ASTM E605, and is used by Under- writers Laboratories. It is light, durable, and … http://www.ritewaythermal.com/wp-content/uploads/2015/09/MK-288R-Prod_Select_Guide.pdf

WebSteel Fireproofing 2. Manufacturer Grace Construction Products 62 Whittemore Avenue Cambridge, MA 02140 (866) 333-3SBM (3726) (617) 876-1400 Fax: (617) 498-4311 ... Field inspection for thickness, density and bond strength by an independent agency is recommended and may be required by the local building code jurisdiction. Any areas with http://www.archcoatings.com/product-pdfs/Grace%20products/MK-6.pdf

WebNov 24, 2024 · Application of MONOKOTE® Fireproofing can be made in the following sequence: For thicknesses of approximately 1⁄2 in. (13 mm) or less, apply in one pass. For thicknesses of 5⁄8 in. (16 mm) or greater, apply subsequent … WebNov 20, 2024 · polyamide (e.g. Intergard 251) at a thickness not exceeding 75 microns (3 mils). Alternatively, a two coat primer system, such as epoxy zinc (e.g. Interzinc 52) and tie coat (e.g. Intergard 269) may be used, and should not exceed 110 microns (4.5 mils) combined dry film thickness. Specific primers have been tested

WebProduct Testing. All of the products that we offer have undergone rigorous testing by both ASTM and Underwriters Laboratory (UL) to verify their physical properties and determine their performance during a fire. UL fire tests are conducted on various construction assemblies and data is used to extrapolate a required thickness for each ...

Web300 Series / ISOLATEK. ®. Type 300 Series &. CAFCO 400 / ISOLATEK Type 400 Series. Quick Resources. how do you spell amethystWebThe min thickness of Spray-Applied Fire Resistive Materials required for various fire resistance ratings of contour sprayed or boxed wide flange columns are shown in the table below: Column Size W/D Min Thkns In. 1 Hr 1-1/2 Hr 2 Hr 3 Hr 4 Hr W6x9 0.33 15/16 1-1/4 1-9/16 2-1/8 2-11/16 W6x12 0.43 13/16 1-1/8 1-7/16 2 2-9/16 phone shop ashton in makerfieldWebchart is applicable to MK-6 HY and is also found in the Association for Specialist Fire protection,( ASFP) “Yellow Book”. Accessory Products Grace has developed the Monokote MK-6 HY Extended Set to allow lines to be left filled at the end of the day, overnight or over the weekend, therefore eliminating the need to pump in or pump out. how do you spell amethyst crystalWebThis program is designed to assist the user in selecting the optimum GCP Applied Technologies Fire Resistance Design based on specific project criteria. It is intended for use in the US market and those markets that utilize the International Building Code (IBC). phone shop arnold nottinghamWebNA. Non-Load Restricted. Beam Only Design for Roof Assemblies. UL S750. PDF. NA. S750 Unres All. S750 Unres MK6GF. S750 Unres Z106HY. how do you spell amicaWebPage 1 10/3/2013 X790 Wide Flange Structural Steel Columns CAFCO® 300 Series, CAFCO® 400 & ISOLATEK® Type 300 Series, ISOLATEK® Type 400 ASTM Desig. W/D phone shop athenryhttp://www.isolatek.com/storage/designs_thickness/2024_ul/Wet%20Mix/X790.pdf how do you spell ammeter